Preparing For Disaster: Designing The Last Building Standing

Learn how mission-critical facilities are designed to be the most resilient buildings.

Mission-critical facilities must be designed to be, if nothing else, the last buildings standing within their communities.

By RMF Engineering
From the June 2024 Issue of Facility Executive

Ā 

Modern public safety infrastructure is essential in ensuring preparedness in times of natural disasters like hurricanes, earthquakes, and tornadoes. Emergency operations centers (EOCs) and emergency communications/ 911 centers (ECCs) are critical to a communityā€™s rapid response capabilities. Decision-makers, agency representatives, incident management personnel, dispatchers, and subject matter experts gather at these facilities to monitor conditions, collect, and share information, establish priorities, and determine protective actions for the public.

Over-communication is crucial in times of crisis, not just within the community, but also more broadly to secure outside support from organizations like the Federal Emergency Management Agency (FEMA). As a result, these mission-critical facilities must be designed to be, if nothing else, the last buildings standing within their communities. As we see more severe weather events across the country, RMF Engineering and SCHRADERGROUP provide insight into how communities prepare for and respond to disaster through the support of uninterrupted emergency communication and operations centers.

mission-critical facilities
Emergency experts gather at these facilities to monitor conditions and establish priorties for public safety. (Photos: Todd Mason of Halkin Mason Photography)

Ā 

Pat McFeely, Public Safety Market Segment Leader at SCHRADERGROUP, and Stephen Devon PE, LEED AP, CxA, Senior Project Manager and Electrical Engineer in RMF Engineeringā€™s Baltimore Buildings Division, share more:

Q: What is driving the increase in demand for new or renovated facilities? Why now?

Pat (SG): With the increase in severe weather events, natural, and man-made disasters, in addition to the combination of aging infrastructure and evolving public safety operations, the requirements for EOC and ECC services have grown and changed. Building codes have changed as well over the years. Essential services buildings must be constructed with newer standards that ensure the facility is still standing after an event and first responders are able to reach the citizens.

Steve (RMF): Technology and data requirements have grown. Building standards have evolved. As dramatic changes in weather patterns become more common, these facilities are critical for the safety of their communities. The population growth in many parts of the country has exposed the limitations of the existing facilities. In most cases, new facilities need to be constructed. Often, existing structures that offer more square footage require significant renovations to modify the building to current standards and be able to ensure essential services are delivered to all residents in moments of crisis.

Q: What are some of the most common challenges you encounter in designing EOCs and ECCs for todayā€™s needs?

Pat (SG): No two EOCs or ECCs are alike. The design and engineering strategies are all tailored around that facilityā€™s unique context and program. Its location, the budget, who works there, and how they work are all things we consider during the initial planning. Budget is critical, and it takes experience to really understand the costs of a renovation or a new facility from feasibility through construction. Grant funding has been used for these facilities in the past, but it does not cover everything. Understanding those costs is essential to working within tight state, county, and local budgets.

These types of facilities are not built like a typical building and need to meet Risk Category 4 as a minimum standard, but to truly be the ā€œlast building standing,ā€ there are several other codes to benchmark against. Based on ICC 500 and FEMA 361 codes and geographical requirements, a facility that isnā€™t rated for wind of certain speed might require a safe roomā€”which would negate the functionality of the rest of the EOC or ECC during a storm if personnel need to abandon their desks.

Steve (RMF):Ā  NFPA 1225 standards also have implications for the mechanical, electrical, and IT infrastructure; these services need to support the mission critical areas, providing power, cooling, and other essential support. Within a fixed floor plan, allocating square footage to accommodate the buildingā€™s infrastructure infringes on what is left for personnel space, equipment storage, or other program requirements. The design team must work efficiently and cost effectively to provide as much program space as possible, while maintaining enough for the robust infrastructure.

Q: When you are looking at new construction, what are some key considerations in planning the design? What does it take to be the ā€œlast building standing?ā€

Pat (SG): When weā€™re assessing a new EOC or ECC site, we follow FEMAā€™s National Risk and Capability Assessment (NRCA) to determine the biggest outside threats. Is the site near a chemical factory, rail lines, or major highways? What is the flood potential? Our job as designers is to ensure that the architecture responds to those risks while still being contextually relevant and welcoming to the community. For example, weā€™ll use natural barriers such as retention ponds to provide standoff where we can, versus fencing the entire property.

Steve (RMF): The threat assessment is also highly valuable in determining what level of utility redundancy will be required, not only for the facilityā€™s primary and back-up mechanical, electrical, and distribution systems, but also for its technology and data infrastructure. By their nature, EOCs and ECCs are incredibly energy intensive facilities, so having a variety of power sources that can support that load continuously is critical. We work closely with the local utility provider to understand their options and limitations for service. Can we bring power in from two separate grids? What on-site generation and storage will be needed? If the site includes a metal comms tower, these systems will need to be grounded to prevent failure in the event of a lightning strike. All of this information helps us determine the equipment that will be required and where it will be sited in terms of the architecture.

Q: What does all this look like when youā€™re inside?

Pat (SG): If weā€™ve designed everything properly, you wonā€™t notice any of these strategies unless youā€™re really looking for them. Emergency services are stressful, demanding, and sometimes tragic, so everything we design is in support of the people performing that work. ECC dispatch areas are tech-dense with large workstations and video walls for news streaming and to provide situational awareness, but we also make sure thereā€™s plenty of natural light. Acoustics also must be thoughtfully considered. We hold space for stress relief and nursing rooms. We design EOC temporary living quarters with the same mentality.

Q: From an engineering perspective, what sorts of redundancy measures are built in to support these spaces?

Steve (RMF): Designing a fully redundant emergency services facility is a highly intricate process. Getting the lights back on after an outage, while essential, is only a small piece of the larger loop. The secondary system must also account for plumbing, HVAC, security, fire protection, IT, and access control. At baseline, this network must follow the code standards for critical operations power systems (COPS).

Back-up power is typically supported by a standby diesel generator and docking station with manual bypass transfer switches for personnel use, guaranteeing uninterrupted functionality for the facility. Ideally, raised floors will house the corresponding distribution network to avoid interrupting interior sight lines. We also use battery powered lighting, which activate instantaneously during an outage. Generators and other large backup systems can take up to 10 seconds to restore lighting, which can feel like a long time to personnel if a space goes completely dark. For data protection and preservation, we design an uninterruptible power supply, or UPS, system with a battery back-up based on the power and raceway demands. This is all tied back into the grounding system.

Q: All that power coming from a diesel generator canā€™t be good for the environment. Are there any sustainability measures you incorporate into these projects?

Pat (SG): Standby diesel-fired generators provide a robust and dependable backup power system; however, a dual fuel arrangement would be good if there is an extended outage for more than three days. Fortunately, diesel fired generators are only exercised once a week for an hour and during emergency situations, where they may run for several days when most other buildings will be offline. This limits their negative impact on the environment. In some cases, dual fuel generators that run on vegetable-based oil (approximately 10% less CO2) can be used for exercising, and diesel fuel will only be used during an extended outage or if fuel needs to be replenished urgently.

Steve (RMF): Sustainability is critical to the long-term success of these facilities because inefficient systems add up to costly maintenance bills. Most of these facilities are using an all-electric HVAC system that is not only supported by the standby generator system, but also eliminates the burning of fossil fuels for heating. At times, we have used solar domestic hot water systems that incorporate storage tanks to facilitate water circulation and deliver solar-preheated water to the domestic water heater, reducing the energy demand of that system. If space allows, solar voltaic panels will be used to supplement the daily electrical power usage.

mission-critical facilities

Pat McFeelyā€™s expertise expands SGā€™s project delivery for facilities supporting law enforcement, fire/EMS, 911 and communications, emergency operations, and other mission critical agencies. His primary responsibilities include leading, operating, and growing the public safety facilities sector. His capabilities include defining the connection between facility and technology, site selection, building and site threat assessments, infrastructure, and technology requirements, and ensuring the proper incorporation of technology and audio-visual systems into facility design.

mission-critical facilitiesSteve Devon is a Senior Project Manager and Electrical Engineer in RMFā€™s Baltimore Buildings Division. He has extensive experience in electrical design for both new construction and building renovations/additions. With over 40 years of consulting engineering experience, he has developed a diverse background in a variety of projects from conceptual design through construction phase services.

Do you have a comment? Share your thoughts in the Comments section below, or send an e-mail to the Editor at jen@groupc.com.

Check out recent articles about emergency preparedness.

Business Continuity, Crisis Management, Disaster Recovery, Featured, Fire & Life Safety, Safety and Security

Business Resiliency, Emergency Preparedness, Natural Disasters, Resilient Buildings, RMF Engineering, SCHRADERGROUP, Sustainability

Sponsored Content
Featured Video

Webinars, Podcasts & Videos

Business Continuity Webinar

Did You Miss Our Latest Business Continuity Webinar?

It's not too late! You can still watch the ā€œBusiness Continuity Exercise Planning and Facilitation Techniques To Start Nowā€ video webinar.

facility resilience webinar

From Prevention To Action: The Role Of Facilities Management In Handling Emergencies And Maintenance

This free webinar on facility resilience will provide actionable strategies to safeguard assets, protect lives, and ensure operational continuity.

adaptive decision-making

Listen Now: Decision-Making During A Crisis

Robert C. Chandler, Ph.D, Founder and Principal of Emperiria discusses his research on adaptive decision-making in this podcast.

Receive the latest articles in your inbox

Share to...